Summary: EN ISO 3744 noise measurement is the most widely used method for determining the sound power level (LWA) of equipment under Outdoor Noise Directive 2000/14/EC. It uses a hemispherical measurement surface over a reflecting plane. Reliable results depend on the right measurement radius, correct microphone positions, a suitable test site and calibrated Class 1 instruments. This guide explains how to set up the measurement on site.
The biggest time loss in noise certification is having to repeat measurements. The wrong radius, a nearby wall, a microphone out of calibration or a windy day can invalidate weeks of preparation. The checkpoints below help you get an acceptable EN ISO 3744 noise measurement the first time.
Which Measurement Method Does 2000/14/EC Use?
Annex III Part A of the Outdoor Noise Directive 2000/14/EC specifies EN ISO 3744 and EN ISO 3746 as the basic noise emission standards for determining sound power level. Part B adds equipment-specific rules: operating conditions, mounting, measurement duration and, where needed, a different measurement surface. In practice, the equipment-specific test code in Annex III Part B takes precedence over the general rules of the basic standard.
Two documents must therefore be read together when planning a measurement:
- EN ISO 3744: general method, corrections, calculation and uncertainty
- 2000/14/EC Annex III Part B: equipment-specific operating conditions (for example load for generators, pressure for compressors, work cycle for construction machinery)
For machine-specific operating conditions, see our article on construction equipment noise measurement. This article focuses on the method itself: the test site and the microphone array.
EN ISO 3744 Noise Measurement Test Site: Reflecting Plane and Free Field
According to Annex III Part A, equipment is measured over a reflecting surface of concrete or non-porous asphalt. For these measurements the environmental correction K2A is set to zero. This makes it essential that the test site really approximates free-field conditions over a reflecting plane: no buildings, walls, vehicles or stacked materials that could cause reflections around the measurement surface.
When choosing a test site, check:
- Is the surface flat, horizontal and large enough to cover the whole measurement surface?
- Is there sufficient distance from reflecting objects outside the measurement radius?
- Is the background noise low enough? Is there traffic, a compressor, a generator or a production line nearby?
- Is the wind speed acceptable for measurement, and are windscreens fitted to the microphones?
Measurement Radius and Microphone Positions
Under Annex III Part A, the radius of the hemisphere must be at least twice the largest dimension of the reference parallelepiped enclosing the equipment, rounded up to the next of the following values: 4 m, 10 m or 16 m.
| Largest dimension of reference parallelepiped | Hemisphere radius (r) | Upper microphone height (0.71 × r) |
|---|---|---|
| Up to 2 m | 4 m | approx. 2.8 m |
| 2 m – 5 m | 10 m | approx. 7.1 m |
| 5 m – 8 m | 16 m | approx. 11.4 m |
The Directive defines 12 microphone positions. Positions 1–8 are at a height of 1.5 m and positions 9–12 at 0.71 × r. If six microphones are used, positions 2, 4, 6, 8, 10 and 12 must be used in any case.
In practice, this means the upper microphones are around 7 m high for a 10 m radius and around 11 m high for a 16 m radius. These heights require sturdy masts, guy lines and fall-arrest attachments for the microphones. A tripod blown over by the wind costs both the measurement and the equipment.

Background Noise and Corrections
EN ISO 3744 uses two correction terms:
- K1 (background noise correction): applied when the difference between the level measured with the equipment running and the background level with the equipment off is not large enough. The larger the difference, the smaller the correction. If the difference is too small, the measurement is not valid. Background noise should therefore be measured at every position, close in time to the equipment measurement, and reported separately.
- K2 (environmental correction): compensates for reflections in the test environment. Under 2000/14/EC, K2A is set to zero for measurements over the reflecting plane, so leaving no reflecting objects nearby is essential.
Instrumentation and Calibration
An acceptable EN ISO 3744 noise measurement needs the following instrument chain:
- A Class 1 sound level meter or multi-channel measurement system to IEC 61672-1
- A Class 1 acoustic calibrator, with calibration checks before and after the measurement and any deviation recorded
- Valid calibration certificates for microphones, preamplifiers, meter and calibrator
- Windscreens, and meteorological measurement to record temperature, humidity and wind speed
A measurement made with uncalibrated or out-of-date instruments cannot be defended in the technical file, however good the result.

What the Measurement Report Should Contain
An EN ISO 3744 noise measurement report should include at least:
- Description of the equipment: serial number, engine and power data, operating condition during measurement
- Description of the test site: surface type, sketch, distances to surrounding objects
- Radius selection and dimensions of the reference parallelepiped
- Microphone positions and heights used
- Measured levels, background levels and K1 corrections for each position
- Meteorological conditions
- Instrument list with serial numbers and calibration dates
- Calculated measured sound power level and uncertainty assessment
For how to move from the measured value to the guaranteed sound power level and how it is shown on the label, see noise marking and the guaranteed sound power level label.
Common Mistakes
- Choosing the radius according to the size of the test site rather than the size of the machine
- Using positions other than 2, 4, 6, 8, 10 and 12 for a six-microphone measurement
- Setting the upper microphones at a fixed height instead of 0.71 × r
- Skipping background noise measurement or measuring at one point only
- Not checking calibration after the measurement
- Measuring at idle instead of the operating condition in Annex III Part B
Frequently Asked Questions
Can an EN ISO 3744 noise measurement be done indoors?
Measurements under 2000/14/EC assume conditions close to a free field over a reflecting plane. Reflections in an enclosed hall change the result, so this condition cannot be met.
Will a notified body accept the manufacturer’s own measurement report?
Under the Annex VI procedure, the manufacturer’s measurement report can be considered. This requires calibrated Class 1 instruments, a written measurement procedure, a competent test engineer and a suitable test site. TESTPLUS verifies these conditions through a factory visit.
Which equipment requires a notified body?
Equipment under Article 12, which is subject to noise limits, requires notified body involvement. See 2000/14/EC Article 12 vs Article 13.
How TESTPLUS Can Help
TESTPLUS is EU Notified Body NB 2908 under Outdoor Noise Directive 2000/14/EC, carrying out conformity assessment under the Annex VI, Annex VII and Annex VIII procedures. We perform every EN ISO 3744 noise measurement with our own calibrated Class 1 equipment, using a test setup that complies with Annex III. See our noise emission and noise tests pages, or contact us.
Sources
- Outdoor Noise Directive 2000/14/EC – EUR-Lex
- EN ISO 3744 – Acoustics – Determination of sound power levels and sound energy levels of noise sources using sound pressure – Engineering methods for an essentially free field over a reflecting plane
- 10 Common Mistakes under the Outdoor Noise Directive 2000/14/EC