Noise marking is the indication of the guaranteed sound power level (LWA) that every item of outdoor equipment covered by Directive 2000/14/EC must carry alongside the CE marking. Its content and form are laid down in Article 11 and Annex IV of the Directive.
This article brings together what the noise label must contain, which value is printed on it, and the proportions and dimensions it has to respect. With the noise label generator in this article, you can enter the sound power level and the label size and download a label drawn to the reference proportions.
- The CE marking must be accompanied by the indication of the guaranteed sound power level.
- The indication consists of the single number in dB, the sign LWA and the pictogram in Annex IV.
- The number is the guaranteed value, not the measured value.
- The label may be reduced or enlarged, but the proportions of the drawing must be respected.
- The vertical dimension should, if possible, not be less than 40 mm.
- It is affixed to each item of equipment in a visible, legible and indelible form.
Contents
What Is the Noise Marking under 2000/14/EC?

Article 11 of Directive 2000/14/EC requires that equipment placed on the market or put into service bears the CE marking accompanied by the indication of the guaranteed sound power level. The model of this indication is given in Annex IV. The obligation applies to both groups of equipment covered by the Directive:
| Equipment group | Requirement | Noise label |
|---|---|---|
| Article 12 – equipment subject to noise limits | The guaranteed sound power level must not exceed the permissible level; a notified body is involved (Annex VI, VII or VIII). | Required |
| Article 13 – equipment subject to noise marking only | No limit value; the manufacturer applies internal control of production (Annex V). | Required |
To find the permissible sound power level for an Article 12 equipment type, use our noise limit calculator.
What the Noise Label Must Contain
According to Annex IV, the indication of the guaranteed sound power level consists of three elements:
- Number: the single number of the guaranteed sound power level in dB.
- Sign: the sign LWA.
- Pictogram: the loudspeaker symbol inside a hexagon, as drawn in Annex IV.

Guaranteed vs Measured Sound Power Level
The Directive distinguishes two values, and only one of them goes on the label:
| Value | Meaning | On the label |
|---|---|---|
| Measured sound power level | The level determined from the measurements described in Annex III, on a single machine representative of the type or as the average of several machines. | No |
| Guaranteed sound power level | The level that also includes the uncertainties due to production variation and measurement procedures, and which the manufacturer or its authorised representative confirms is not exceeded. | Yes |
Both values are stated in the EC declaration of conformity, and the value on the label must match the guaranteed value in the declaration. For Article 12 equipment, you can compare the guaranteed value with the limit in the noise limit calculator.
Noise Label Dimensions
Annex IV sets two rules for the size of the label:
- Proportions: If the indication is reduced or enlarged according to the size of the equipment, the proportions of the drawing must be respected.
- Minimum size: The vertical dimension of the indication should, if possible, not be less than 40 mm.
| Code | Dimension | Reference drawing | At 40 mm height | At 60 mm height |
|---|---|---|---|---|
| A | Overall height | 100 mm | 40 mm | 60 mm |
| B | Inner frame height | 88 mm | 35.2 mm | 52.8 mm |
| C | Outer border margin, top and bottom | 6 mm | 2.4 mm | 3.6 mm |
| D | Inner margin above the pictogram and below the number | 3 mm | 1.2 mm | 1.8 mm |
| E | Height of the pictogram and LWA sign | 32 mm | 12.8 mm | 19.2 mm |
| F | Gap between the pictogram and the number | 4 mm | 1.6 mm | 2.4 mm |
| G | Height of the number | 46 mm | 18.4 mm | 27.6 mm |
| H | Overall width | 90 mm | 36 mm | 54 mm |
| I | Inner frame width | 78 mm | 31.2 mm | 46.8 mm |
| J | Outer border margin, left and right | 6 mm | 2.4 mm | 3.6 mm |
The dimensions in the table are calculated from the reference drawing above (scale = label height ÷ 100).
Noise Label Generator
Enter the guaranteed sound power level and the label height (A) or width (H). The generator draws the label to the reference proportions and lists every dimension by its letter code. Labels below 40 mm in height are not generated. If your equipment is subject to a noise limit, check the limit first with the noise limit calculator.

Height and width are linked (H = A × 0.9); changing one updates the other. The maximum value that can be entered is 194 dB.
| Code | Dimension | Reference | Result |
|---|---|---|---|
| A | Overall height | 100 | – |
| B | Inner frame height | 88 | – |
| C | Outer border margin, top and bottom | 6 | – |
| D | Inner margin above the pictogram and below the number | 3 | – |
| E | Height of the pictogram and LWA sign | 32 | – |
| F | Gap between the pictogram and the number | 4 | – |
| G | Height of the number | 46 | – |
| H | Overall width | 90 | – |
| I | Inner frame width | 78 | – |
| J | Outer border margin, left and right | 6 | – |
Sound travels as pressure waves: air molecules are alternately compressed and expanded. At about 194 dB, the low-pressure side of the sound wave drops to a complete vacuum (zero pressure). Because air cannot expand any further, a “sound wave” louder than this cannot form in the Earth’s atmosphere under normal conditions; beyond that point it becomes a shock wave. Strictly speaking, this limit applies to sound pressure level, while the label shows sound power level (LWA), which is a different quantity; the generator simply uses 194 dB as its upper bound.
Disclaimer: This generator is not an official tool and is provided for information purposes only. Always check the label against the current legislation and requirements before use. The manufacturer remains responsible for the guaranteed value and for the conformity of the final label; TESTPLUS accepts no liability for labels produced with this tool.
How the Marking Must Be Affixed

- The CE marking and the indication of the guaranteed sound power level must be affixed visibly, legibly and indelibly to each item of equipment.
- Markings or inscriptions likely to mislead as to the meaning or form of the CE marking or the noise indication are prohibited.
- Other markings may be affixed, provided that they do not reduce the visibility and legibility of the CE marking and the noise indication.
Common Noise Marking Mistakes
- Printing the measured value instead of the guaranteed value.
- A label value that differs from the guaranteed value in the EC declaration of conformity.
- Stretching or compressing the label so that the proportions are no longer respected.
- Using a label smaller than 40 mm in height although the equipment has room for a larger one.
- Labels that fade or peel off and are therefore not indelible.
- Omitting the label on Article 13 equipment on the assumption that it is only needed where noise limits apply.
Frequently Asked Questions
Is the noise label required for equipment that has no noise limit?
Yes. Equipment subject to noise marking only (Article 13) must also carry the CE marking together with the indication of the guaranteed sound power level.
Which value is printed on the label?
The guaranteed sound power level, as a single number in dB. The measured value appears in the EC declaration of conformity and the technical documentation, not on the label.
Can the label be smaller than 40 mm?
Annex IV states that the vertical dimension should, if possible, not be less than 40 mm. A smaller label is therefore only justified where the size of the equipment does not allow it, and the proportions of the drawing must still be respected.
Who affixes the noise label?
The manufacturer or its authorised representative established in the Community. This also applies where a notified body is involved in the conformity assessment.
Conformity Assessment with TESTPLUS
Affixing the noise label is the last step of the conformity assessment under Directive 2000/14/EC. TESTPLUS (NB 2908) carries out conformity assessment for 2000/14/EC noise emission; for the Directive itself, see our article on Directive 2000/14/EC, for limit values, the noise limit calculator; and for the CE marking, the CE marking rules and dimensions.
The dimensions in this article are taken from the reference drawing shown above; always check the final label against Annex IV of the Directive.
Sources: Directive 2000/14/EC (EUR-Lex)
Related Noise Certification Guides
This guide is part of the Outdoor Noise Directive 2000/14/EC certification resources of TESTPLUS, Notified Body NB 2908 (see our NANDO listing).
- Noise certification process step by step (2000/14/EC)
- Noise testing: sound power level (LWA) measurement
- Article 12 vs Article 13: noise limits or marking only?
- Common mistakes in 2000/14/EC noise certification
- Generator noise level regulations and compliance
- Compressor noise compliance under 2000/14/EC
- Construction equipment noise measurement
- Lift trucks under the Outdoor Noise Directive