Skip to main content

Noise marking is the indication of the guaranteed sound power level (LWA) that every item of outdoor equipment covered by Directive 2000/14/EC must carry alongside the CE marking. Its content and form are laid down in Article 11 and Annex IV of the Directive.

This article brings together what the noise label must contain, which value is printed on it, and the proportions and dimensions it has to respect. With the noise label generator in this article, you can enter the sound power level and the label size and download a label drawn to the reference proportions.

Noise marking rules in brief:
  • The CE marking must be accompanied by the indication of the guaranteed sound power level.
  • The indication consists of the single number in dB, the sign LWA and the pictogram in Annex IV.
  • The number is the guaranteed value, not the measured value.
  • The label may be reduced or enlarged, but the proportions of the drawing must be respected.
  • The vertical dimension should, if possible, not be less than 40 mm.
  • It is affixed to each item of equipment in a visible, legible and indelible form.

What Is the Noise Marking under 2000/14/EC?

Sound power measurement of a lawnmower with six microphones

Article 11 of Directive 2000/14/EC requires that equipment placed on the market or put into service bears the CE marking accompanied by the indication of the guaranteed sound power level. The model of this indication is given in Annex IV. The obligation applies to both groups of equipment covered by the Directive:

Equipment groupRequirementNoise label
Article 12 – equipment subject to noise limitsThe guaranteed sound power level must not exceed the permissible level; a notified body is involved (Annex VI, VII or VIII).Required
Article 13 – equipment subject to noise marking onlyNo limit value; the manufacturer applies internal control of production (Annex V).Required

To find the permissible sound power level for an Article 12 equipment type, use our noise limit calculator.

What the Noise Label Must Contain

According to Annex IV, the indication of the guaranteed sound power level consists of three elements:

  1. Number: the single number of the guaranteed sound power level in dB.
  2. Sign: the sign LWA.
  3. Pictogram: the loudspeaker symbol inside a hexagon, as drawn in Annex IV.
Guaranteed sound power level (LWA) label under Directive 2000/14/EC with reference dimensions in mm
Guaranteed sound power level label with reference dimensions (100 mm × 90 mm). The value 104 dB is an example.

Guaranteed vs Measured Sound Power Level

The Directive distinguishes two values, and only one of them goes on the label:

ValueMeaningOn the label
Measured sound power levelThe level determined from the measurements described in Annex III, on a single machine representative of the type or as the average of several machines.No
Guaranteed sound power levelThe level that also includes the uncertainties due to production variation and measurement procedures, and which the manufacturer or its authorised representative confirms is not exceeded.Yes

Both values are stated in the EC declaration of conformity, and the value on the label must match the guaranteed value in the declaration. For Article 12 equipment, you can compare the guaranteed value with the limit in the noise limit calculator.

Noise Label Dimensions

Annex IV sets two rules for the size of the label:

  1. Proportions: If the indication is reduced or enlarged according to the size of the equipment, the proportions of the drawing must be respected.
  2. Minimum size: The vertical dimension of the indication should, if possible, not be less than 40 mm.
CodeDimensionReference drawingAt 40 mm heightAt 60 mm height
AOverall height100 mm40 mm60 mm
BInner frame height88 mm35.2 mm52.8 mm
COuter border margin, top and bottom6 mm2.4 mm3.6 mm
DInner margin above the pictogram and below the number3 mm1.2 mm1.8 mm
EHeight of the pictogram and LWA sign32 mm12.8 mm19.2 mm
FGap between the pictogram and the number4 mm1.6 mm2.4 mm
GHeight of the number46 mm18.4 mm27.6 mm
HOverall width90 mm36 mm54 mm
IInner frame width78 mm31.2 mm46.8 mm
JOuter border margin, left and right6 mm2.4 mm3.6 mm

The dimensions in the table are calculated from the reference drawing above (scale = label height ÷ 100).

Noise Label Generator

Enter the guaranteed sound power level and the label height (A) or width (H). The generator draws the label to the reference proportions and lists every dimension by its letter code. Labels below 40 mm in height are not generated. If your equipment is subject to a noise limit, check the limit first with the noise limit calculator.

Guaranteed sound power level (LWA) label with dimension codes A to J
Letter codes used in the generator.

Height and width are linked (H = A × 0.9); changing one updates the other. The maximum value that can be entered is 194 dB.

Enter the sound power level and the label size.
CodeDimensionReferenceResult
AOverall height100–
BInner frame height88–
COuter border margin, top and bottom6–
DInner margin above the pictogram and below the number3–
EHeight of the pictogram and LWA sign32–
FGap between the pictogram and the number4–
GHeight of the number46–
HOverall width90–
IInner frame width78–
JOuter border margin, left and right6–
Did you know? Why 194 dB is the limit
Sound travels as pressure waves: air molecules are alternately compressed and expanded. At about 194 dB, the low-pressure side of the sound wave drops to a complete vacuum (zero pressure). Because air cannot expand any further, a “sound wave” louder than this cannot form in the Earth’s atmosphere under normal conditions; beyond that point it becomes a shock wave. Strictly speaking, this limit applies to sound pressure level, while the label shows sound power level (LWA), which is a different quantity; the generator simply uses 194 dB as its upper bound.

Disclaimer: This generator is not an official tool and is provided for information purposes only. Always check the label against the current legislation and requirements before use. The manufacturer remains responsible for the guaranteed value and for the conformity of the final label; TESTPLUS accepts no liability for labels produced with this tool.

How the Marking Must Be Affixed

Guaranteed sound power level label of 104 dB on a generator enclosure
  • The CE marking and the indication of the guaranteed sound power level must be affixed visibly, legibly and indelibly to each item of equipment.
  • Markings or inscriptions likely to mislead as to the meaning or form of the CE marking or the noise indication are prohibited.
  • Other markings may be affixed, provided that they do not reduce the visibility and legibility of the CE marking and the noise indication.

Common Noise Marking Mistakes

  • Printing the measured value instead of the guaranteed value.
  • A label value that differs from the guaranteed value in the EC declaration of conformity.
  • Stretching or compressing the label so that the proportions are no longer respected.
  • Using a label smaller than 40 mm in height although the equipment has room for a larger one.
  • Labels that fade or peel off and are therefore not indelible.
  • Omitting the label on Article 13 equipment on the assumption that it is only needed where noise limits apply.

Frequently Asked Questions

Is the noise label required for equipment that has no noise limit?

Yes. Equipment subject to noise marking only (Article 13) must also carry the CE marking together with the indication of the guaranteed sound power level.

Which value is printed on the label?

The guaranteed sound power level, as a single number in dB. The measured value appears in the EC declaration of conformity and the technical documentation, not on the label.

Can the label be smaller than 40 mm?

Annex IV states that the vertical dimension should, if possible, not be less than 40 mm. A smaller label is therefore only justified where the size of the equipment does not allow it, and the proportions of the drawing must still be respected.

Who affixes the noise label?

The manufacturer or its authorised representative established in the Community. This also applies where a notified body is involved in the conformity assessment.

Conformity Assessment with TESTPLUS

Affixing the noise label is the last step of the conformity assessment under Directive 2000/14/EC. TESTPLUS (NB 2908) carries out conformity assessment for 2000/14/EC noise emission; for the Directive itself, see our article on Directive 2000/14/EC, for limit values, the noise limit calculator; and for the CE marking, the CE marking rules and dimensions.

To apply for conformity assessment, contact our technical team. For other questions about noise emission, see our frequently asked questions page.

The dimensions in this article are taken from the reference drawing shown above; always check the final label against Annex IV of the Directive.

Sources: Directive 2000/14/EC (EUR-Lex)

This guide is part of the Outdoor Noise Directive 2000/14/EC certification resources of TESTPLUS, Notified Body NB 2908 (see our NANDO listing).