Short answer: outdoor equipment certified with the involvement of an EU notified body under Directive 2000/14/EC can be CE marked and placed on the market in the European Union, in Northern Ireland and in Great Britain. Under the amendment that came into force in Great Britain on 13 April 2026, recognition of CE marking for outdoor noise equipment has been extended indefinitely. One certificate from TESTPLUS, Notified Body NB 2908, therefore covers all three markets.
Which Rules Apply in the UK?
Since Brexit, two legal frameworks apply to noise emission from equipment for use outdoors:
- Great Britain (England, Scotland and Wales): the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 (SI 2001/1701), as amended. In the GB text, the conformity assessment procedures appear as Annexes E, F and G; they correspond to Annexes VI, VII and VIII of the EU Directive.
- Northern Ireland: under the Windsor Framework, EU product rules continue to apply, so Directive 2000/14/EC applies directly.
The equipment lists, the noise limits and the measurement methods are equivalent in both texts: the same 22 types of equipment are subject to noise limits (Article 12) and the same 41 types are subject to noise marking only (Article 13). See Article 12 vs Article 13 for the difference.
CE, UKCA or UKNI? Marking by Market
Which marking you may use depends on who carried out the conformity assessment and where the product is placed on the market:
| Market | Assessed by an EU notified body (e.g. NB 2908) | Assessed by a UK approved body |
|---|---|---|
| European Union | CE marking | Not accepted |
| Northern Ireland | CE marking | CE + UKNI marking (cannot then be sold in the EU) |
| Great Britain | CE marking (recognised indefinitely) or UKCA marking | UKCA marking only |
For a manufacturer who sells in more than one of these markets, a certificate issued by an EU notified body is the only route that leads to a single marking accepted in all of them. For a broader comparison of the two markings, see CE marking vs UKCA in Great Britain.
Equipment That Needs a Notified Body
For equipment subject to noise limits (Article 12), a notified body must be involved before the equipment can be CE marked. Typical examples are:
- Power generators below 400 kW and welding generators
- Compressors below 350 kW
- Excavators, loaders, dozers, dumpers and backhoe-loaders
- Compaction machines, hand-held concrete breakers and picks
- Tower cranes, construction winches and hydraulic power packs
- Lawn mowers, lawn trimmers and lawn edge trimmers
- Rough-terrain and high-capacity lift trucks (see lift trucks under 2000/14/EC)
The notified body carries out one of the procedures of Annex VI, VII or VIII (Annexes E, F or G in the GB text). Equipment subject to noise marking only (Article 13) can be declared by the manufacturer; voluntary third-party verification of the guaranteed sound power level is also available.
Responsible Person, Documentation and Label
- Responsible person in GB: the manufacturer or its authorised representative. If neither is established in the UK, the obligations apply to the person placing the equipment on the GB market. An authorised representative for GB must be based in the UK.
- Technical documentation: must be kept for at least 10 years after the last unit is manufactured.
- Declaration of conformity: must name the person who keeps the technical documentation. Since the 2025 amendment, a copy no longer has to be sent to the Secretary of State.
- Noise label: the guaranteed sound power level (LWA) must be shown next to the CE or UKCA marking. See the noise label guide. In GB, the UKCA marking may be affixed on a label until 31 December 2027.
TESTPLUS for UK and EU Noise Certification
TESTPLUS is a notified body for the Outdoor Noise Directive 2000/14/EC, identification number 2908, listed in the European Commission’s NANDO database. TESTPLUS is one of only seven bodies worldwide notified under all three of the Outdoor Noise Directive, the Machinery Directive and the EMC Directive, so noise, machinery and EMC conformity assessment can be handled by a single body.
TESTPLUS carries out all three notified body procedures of Directive 2000/14/EC: Annex VI (internal control of production with assessment of technical documentation and periodic checking), Annex VII (unit verification) and Annex VIII (full quality assurance). For small batches or individually imported units, Annex VII unit verification is usually the most practical route; for series production, Annex VI or Annex VIII is generally preferred.
Manufacturers and importers in the UK can reach us through our London contact office: +44 7760 682877. See the noise certification process for the steps, or request a quotation through our contact page.
Frequently Asked Questions
Can I sell CE-marked outdoor equipment in Great Britain?
Yes. CE marking under Directive 2000/14/EC, including CE marking based on an EU notified body assessment, is recognised in Great Britain without a time limit. The equipment must comply with the current version of the Directive.
Do I need UKCA marking as well as CE?
No, not when the conformity assessment was carried out by an EU notified body. UKCA marking becomes mandatory for GB only where a UK approved body carried out the assessment.
Which marking do I need for Northern Ireland?
CE marking. If a UK approved body carried out the assessment instead of an EU notified body, the UKNI marking must be added next to the CE marking, and the product can then not be sold in the EU.
Is the noise limit the same in GB and in the EU?
Yes. The GB Regulations reproduce the equipment types, the limit values and the measurement methods of Directive 2000/14/EC.