Skip to main content

Summary: Sound power level (LWA) is the total acoustic energy a machine emits, expressed in decibels. Unlike sound pressure level, it does not depend on distance or the room, which is why the Outdoor Noise Directive 2000/14/EC uses it to set noise limits and labels. The measured sound power level comes from tests to EN ISO 3744; the guaranteed sound power level adds the uncertainties and is the value shown on the noise label and in the declaration of conformity.

Questions about sound power level usually come up when a distributor asks for the noise label or when a test report shows a value close to the limit. This guide explains what LWA means, how it is measured and how the guaranteed value is set.

What Is Sound Power Level (LWA)?

Sound power is the rate at which a source emits acoustic energy, measured in watts. Because the values are very small, it is expressed as a level in decibels relative to 1 picowatt (10-12 W). LWA is the A-weighted sound power level, which reflects how the human ear perceives noise.

Sound power is a property of the machine itself. A generator with an LWA of 95 dB has the same sound power level whether it stands in a field or next to a building. This makes LWA suitable for comparing products and for setting legal limits.

Sound Power Level vs Sound Pressure Level

Sound power level (LWA) Sound pressure level (LpA)
What it describes Total noise emitted by the source Noise heard at a specific point
Depends on distance and room No Yes
How it is obtained Calculated from sound pressure measured on a surface around the source Measured directly with a sound level meter
Where it is used 2000/14/EC limits and noise label, product comparison Operator exposure, workplace noise, instructions under the Machinery Directive

A sound level meter reading is a sound pressure level. Sound power level cannot be read directly; it is calculated from several measurements around the machine.

How Is Sound Power Level Measured?

Annex III of Directive 2000/14/EC uses EN ISO 3744 as the basic measurement method, with specific operating conditions for each type of equipment in Part B. EN ISO 3744 is an engineering-grade (grade 2) method for an essentially free field over a reflecting plane. EN ISO 3746 is a survey-grade (grade 3) method with a larger uncertainty, often used for screening.

In an EN ISO 3744 measurement:

  1. The machine is placed on a hard reflecting surface, away from walls and other reflecting objects.
  2. Microphones are positioned on a hemisphere (or box) around the machine at the radius set for the equipment type.
  3. The machine runs in the operating condition defined in Annex III Part B.
  4. The average sound pressure level over the measurement surface is corrected for background noise (K1) and the test environment (K2).
  5. The sound power level is calculated by adding the measurement surface term: LWA = LpA + 10 log10(S/S0), where S is the area of the measurement surface and S0 = 1 m².

Measurement instruments must be Class 1 and calibrated before and after the measurement. For a practical setup guide, see EN ISO 3744 noise measurement: test site and microphone array.

Measured vs Guaranteed Sound Power Level

Directive 2000/14/EC distinguishes two values:

  • Measured sound power level: the value obtained from the EN ISO 3744 measurement on one or more units.
  • Guaranteed sound power level: the measured value plus the uncertainties due to production variation and the measurement procedure. The manufacturer confirms that no unit placed on the market will exceed it (Article 3 of the directive).

The guaranteed value is the one that appears on the noise label, in the EC declaration of conformity and in the notified body’s assessment. For Article 12 equipment, the guaranteed sound power level must not exceed the permissible sound power level for the equipment type. You can check the limit for your equipment with the noise limit calculator.

Where the Sound Power Level Must Be Shown

  • Noise label: outdoor equipment carries the CE marking together with the guaranteed sound power level (LWA in dB) in the format set by Annex IV. See noise marking and the guaranteed sound power level label.
  • EC declaration of conformity: it states the measured and the guaranteed sound power level for the equipment.
  • Instructions under the Machinery Directive: where the A-weighted emission sound pressure level at workstations exceeds 80 dB(A), the instructions must also state the sound power level of the machine.

Common Mistakes

  • Putting a sound pressure level reading (for example “85 dB at 7 m”) on the label instead of the guaranteed sound power level.
  • Labelling the measured value without adding the uncertainties.
  • Measuring indoors or near walls, which inflates the result.
  • Testing at idle instead of the operating condition in Annex III Part B.
  • Using a guaranteed value that does not cover production variation, so that units from later batches exceed it.

Frequently Asked Questions

Is sound power level the same as the decibel reading on a sound level meter?

No. A sound level meter shows the sound pressure level at one point. The sound power level is calculated from many measurements around the machine and does not depend on distance.

Can a sound power level be lower than the sound pressure level?

For most outdoor machines the sound power level is higher than the sound pressure level measured a few metres away, because it represents the total noise emitted in all directions.

Do US manufacturers need a sound power label for the EU?

Yes. Equipment within the scope of Directive 2000/14/EC must carry the guaranteed sound power level label when placed on the EU market, wherever it is manufactured. Article 12 equipment also needs notified body involvement. See CE marking requirements for US manufacturers.

How TESTPLUS Can Help

TESTPLUS is EU Notified Body NB 2908 under the Outdoor Noise Directive 2000/14/EC and carries out conformity assessment under the Annex VI, Annex VII and Annex VIII procedures. We perform sound power measurements to EN ISO 3744 with our own calibrated Class 1 equipment, in a test setup that complies with Annex III. See our noise certification and noise tests pages, or contact us.

Sources

  • Outdoor Noise Directive 2000/14/EC – EUR-Lex
  • Machinery Directive 2006/42/EC – EUR-Lex
  • EN ISO 3744 – Acoustics – Determination of sound power levels and sound energy levels of noise sources using sound pressure – Engineering methods for an essentially free field over a reflecting plane
  • EN ISO 3746 – Acoustics – Determination of sound power levels and sound energy levels of noise sources using sound pressure – Survey method using an enveloping measurement surface over a reflecting plane