Skip to main content

Outdoor Noise Directive 2000/14/EC
Notified Body Certification

A noise certificate is the document issued by a notified body showing that equipment for use outdoors complies with the Outdoor Noise Directive 2000/14/EC. It is required for machines subject to noise limits (Article 12).

Noise certification with Notified Body NB 2908

We act as the notified body under all three conformity assessment procedures of Directive 2000/14/EC and carry out the sound power level (LWA) measurements with our own Class 1 equipment.

Annex VIInternal control of production with assessment of technical documentation and periodical checking. For series production.
Annex VIIUnit verification. Each item is verified individually; for one-off machines and small batches.
Annex VIIIFull quality assurance. For manufacturers with a quality system covering design and production.

Directive 2000/14/EC (as amended by 2005/88/EC), known as the Outdoor Noise Directive, aims to limit the noise emitted into the environment by equipment for use outdoors. Türkiye applies the same requirements through its harmonised Regulation on Noise Emission in the Environment by Equipment for Use Outdoors. The Directive sets noise emission limits, conformity assessment procedures, and rules for technical documentation and marking, protecting human health while supporting the smooth functioning of the internal market.

Equipment in scope falls into two groups:

  • Article 12 – Equipment subject to noise limits: The guaranteed sound power level must not exceed the permissible limit set in the Directive. A notified body must be involved in the conformity assessment.
  • Article 13 – Equipment subject to noise marking only: No limit applies; the guaranteed sound power level must be determined and declared on the product.

Out of scope: Equipment primarily intended for the transport of goods or persons by road, rail, air or on waterways; equipment specially designed and constructed for military and police purposes and for emergency services; and non-powered attachments that are separately placed on the market or put into service (except hand-held concrete-breakers and picks and hydraulic hammers).

Notified Body for the Outdoor Noise Directive (NB 2908)

TESTPLUS is a notified body for the Outdoor Noise Directive 2000/14/EC, identification number 2908, published in the European Commission’s NANDO database and accredited by TÜRKAK (AB-0155-U). As a 2000/14/EC notified body, we carry out the conformity assessment procedures that require notified body involvement for Article 12 equipment, such as construction machinery, compressors, generators, lawn mowers and other equipment for use outdoors, and we provide voluntary third-party verification of the guaranteed sound power level for Article 13 equipment. TESTPLUS also covers machinery and EMC – see our CE certification and CE testing overview.

TESTPLUS is one of only seven bodies worldwide notified under all three of the Outdoor Noise Directive (2000/14/EC), the Machinery Directive (2006/42/EC) and the EMC Directive (2014/30/EU), so noise, machinery and EMC certification of the same product can be handled by a single notified body.

On this page: Article 12 equipment · Article 13 equipment · Procedures · Noise measurement · Noise limit calculator · Importing into Türkiye (TAREKS) · FAQ

Article 12: Equipment Subject to Noise Limits (22 Types)

Construction machinery subject to noise limits: excavator and roller compactor

The following equipment is subject to noise limits. For this equipment, conformity assessment by a notified body under Annex VI, Annex VII or Annex VIII is mandatory.

  • Builders’ hoists for the transport of goods (combustion-engine driven)
  • Compaction machines (only vibrating and non-vibrating rollers, vibratory plates and vibratory rammers)
  • Compressors (< 350 kW)
  • Concrete-breakers and picks, hand-held
  • Construction winches (combustion-engine driven)
  • Dozers (< 500 kW)
  • Dumpers (< 500 kW)
  • Excavators, hydraulic or rope-operated (< 500 kW)
  • Excavator-loaders (< 500 kW)
  • Graders (< 500 kW)
  • Hydraulic power packs
  • Landfill compactors, loader-type with bucket (< 500 kW)
  • Lawnmowers (excluding agricultural and forestry equipment, multi-purpose devices and equipment whose main motorised component has an installed power of more than 20 kW)
  • Lawn trimmers / lawn edge trimmers
  • Lift trucks, combustion-engine driven, counterbalanced (excluding standard lift trucks with a rated capacity of not more than 10 tonnes)
  • Loaders (< 500 kW)
  • Mobile cranes
  • Motor hoes (< 3 kW)
  • Paver-finishers (excluding those equipped with a high-compaction screed)
  • Power generators (< 400 kW)
  • Tower cranes
  • Welding generators

Article 13: Equipment Subject to Noise Marking Only (41 Types)

Outdoor equipment subject only to noise marking

No limit applies to the following equipment; however, the sound power level must be measured, the guaranteed value must be shown on the product together with the CE marking, and it must be stated in the EC declaration of conformity.

  • Aerial access platforms (combustion-engine driven)
  • Brush cutters
  • Builders’ hoists for the transport of goods (with electric motor)
  • Building site band saw machines
  • Building site circular saw benches
  • Chain saws, portable
  • Combined high pressure flushers and suction vehicles
  • Compaction machines (explosion rammers only)
  • Concrete or mortar mixers
  • Construction winches (with electric motor)
  • Conveying and spraying machines for concrete and mortar
  • Conveyor belts
  • Cooling equipment on vehicles
  • Drill rigs
  • Equipment for loading and unloading silos or tanks on trucks
  • Glass recycling containers
  • Grass trimmers / grass edge trimmers
  • Hedge trimmers
  • High pressure flushers
  • High pressure water jet machines
  • Hydraulic hammers
  • Joint cutters
  • Leaf blowers
  • Leaf collectors
  • Lift trucks, combustion-engine driven, counterbalanced (only standard lift trucks with a rated capacity of not more than 10 tonnes)
  • Mobile waste containers
  • Paver-finishers (equipped with a high-compaction screed)
  • Piling equipment
  • Pipelayers
  • Piste caterpillars
  • Power generators (≥ 400 kW)
  • Power sweepers
  • Refuse collection vehicles
  • Road milling machines
  • Scarifiers
  • Shredders / chippers
  • Snow-removing machines with rotating tools (self-propelled, excluding attachments)
  • Suction vehicles
  • Trenchers
  • Truck mixers
  • Water pump units (not for use under water)

Conformity Assessment Procedures for Noise Certification (2000/14/EC)

Noise emission measurement with a Class 1 precision sound level meter

Under Article 14 of the Directive, the applicable procedure depends on the group the equipment belongs to:

  • Article 12 equipment (subject to noise limits): The manufacturer chooses one of the following three procedures; a notified body must be involved in all three.
    • Annex VI – Internal control of production with assessment of technical documentation and periodical checking: The most common route for series production. The notified body assesses the technical documentation and the noise measurement, then monitors the conformity of production through periodical checks.
    • Annex VII – Unit verification: Each item of equipment is verified individually; suitable for one-off machines or small quantities.
    • Annex VIII – Full quality assurance: The manufacturer’s quality system covering design, production and testing is approved and audited by the notified body.
  • Article 13 equipment (marking only): Internal control of production under Annex V is sufficient; no notified body is required. The manufacturer has the noise measured, draws up the technical documentation and declares the guaranteed sound power level.

Voluntary Third-Party Noise Verification for Article 13 Equipment

For the equipment listed in Article 13, the Directive does not require a notified body: the manufacturer measures the noise emission, determines the guaranteed sound power level and affixes the noise marking under the Annex V internal control of production procedure. Responsibility for the declared value therefore rests with the manufacturer alone.

TESTPLUS also serves this area on a voluntary basis as an independent third-party body. The benefits for the manufacturer are:

  • Impartial evidence: the measured and guaranteed sound power level is verified by a body with no interest in the result
  • Early detection: measurement or documentation errors are identified before the equipment reaches the market
  • Commercial confidence: buyers, importers and tender authorities receive documentation from an independent body
  • Readiness: the manufacturer is better prepared for market surveillance and import inspections

Voluntary certificates are issued outside our notified body scope and do not replace the manufacturer’s declaration of conformity.

How Is Noise Measured?

Sound power measurement with a hemispherical microphone array (ISO 3744)

Measurements are carried out according to the noise test code defined for each type of equipment in Annex III of the Directive. The basic measurement standard is EN ISO 3744: the equipment is placed on a reflecting plane at the centre of a hemispherical measurement surface, and the A-weighted sound power level (LWA) is calculated from the sound pressure levels measured at the microphone positions on that surface. Operating conditions (idling, full load, hydraulic cycle, travelling, etc.) are set by the test code; background noise and the environmental correction are checked. Provided a suitable test area is available, measurements can be made at the manufacturer’s premises or at an open test site. For details, see our article on construction equipment noise measurement.

Guaranteed Sound Power Level and the Noise Label

The guaranteed sound power level is determined by adding the measurement uncertainty and the variations in series production to the measured sound power level. This value is shown on the equipment next to the CE marking in the form “LWA … dB”, following the model in Annex IV, in a visible, legible and indelible manner, and is stated in the EC declaration of conformity. For Article 12 equipment, the guaranteed value must not exceed the limit determined by the machine’s net installed power, electric power, mass or cutting width. You can check the limit with the calculator below.

Noise certification under 2000/14/EC – CE marking and Annex IV guaranteed sound power level LWA label
CE marking and guaranteed sound power level (LWA) label according to the Annex IV model (dimensions in mm)

Noise Limit Calculator and Limit Values

For Article 12 equipment, select the machine type and enter the relevant parameter to calculate the permissible sound power level (LWA); enter your guaranteed value to see whether it meets the limit. The full table of Stage II limit values is given below the calculator.

Permissible sound power level
—
Select a machine and enter the value.

This calculator is for information only; the binding texts are Directive 2000/14/EC (as amended by 2005/88/EC) and the national legislation transposing it.

2000/14/EC Noise Limit Values (Article 12 – Stage II)

For outdoor equipment covered by Article 12 of the Directive, the guaranteed A-weighted sound power level (LWA, dB / 1 pW) must not exceed the limits below. The limits depend on the machine’s net installed power (P, kW), for generators the electric power (Pel, kW), for breakers the mass (m, kg), and for lawnmowers the cutting width (L, cm).

Type of equipmentParameter rangeLimit LWA (dB)
Compaction machines (vibrating rollers, vibratory plates, vibratory rammers)P ≤ 8105(2)
8 < P ≤ 70106(2)
P > 7086 + 11 lg P(2)
Tracked dozers, tracked loaders, tracked excavator-loadersP ≤ 55103(2)
P > 5584 + 11 lg P(2)
Wheeled dozers, wheeled loaders, wheeled excavator-loaders (backhoe loaders), dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, mobile cranes, non-vibrating rollers, paver-finishers, hydraulic power packsP ≤ 55101(2)
P > 5582 + 11 lg P(2)
Excavators, builders’ hoists for the transport of goods, construction winches, motor hoesP ≤ 1593
P > 1580 + 11 lg P
Hand-held concrete-breakers and picksm ≤ 15105
15 < m < 3092 + 11 lg m(2)
m ≥ 3094 + 11 lg m
Tower cranes—96 + lg P
Welding and power generators(1)Pel ≤ 295 + lg Pel
2 < Pel ≤ 1096 + lg Pel
Pel > 1095 + lg Pel
CompressorsP ≤ 1597
P > 1595 + 2 lg P
Lawnmowers, lawn trimmers / lawn edge trimmersL ≤ 5094(2)
50 < L ≤ 7098
70 < L ≤ 12098(2)
L > 120103(2)

(1) For welding generators, Pel is the conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor. For power generators, Pel is the prime power according to ISO 8528-1, clause 13.3.2.
(2) The Stage II values are merely indicative for the following equipment, for which the Stage I values continue to apply: walk-behind vibrating rollers, vibratory plates (> 3 kW), vibratory rammers, dozers with steel tracks, loaders with steel tracks (> 55 kW), combustion-engine driven counterbalanced lift trucks, paver-finishers with a compaction screed, hand-held combustion-engine driven concrete-breakers and picks (15 < m < 30 kg), lawnmowers and lawn trimmers / lawn edge trimmers (L ≤ 50, 70 < L ≤ 120 and L > 120 cm).
The calculated limit is rounded to the nearest whole number (down if less than 0.5, up if 0.5 or more). “lg” is the base-10 logarithm.

Technical Documentation and EC Declaration of Conformity

The technical documentation contains the manufacturer’s details, a description of the equipment, the noise test code and measurement method applied, the measurement results and reports, how the guaranteed sound power level was determined, and the measures ensuring the conformity of series production. The EC declaration of conformity states the type of equipment, the procedure applied, the measured and guaranteed sound power levels and, for Article 12 equipment, the name and number of the notified body. The documents must be kept for 10 years after the last item is manufactured.

Lift Trucks and Special Cases

For combustion-engine driven counterbalanced lift trucks, the obligation depends on the type: standard lift trucks with a rated capacity of not more than 10 tonnes are subject to marking only (Article 13), while rough-terrain trucks and lift trucks above 10 tonnes are subject to noise limits and notified body assessment (Article 12).
Importing into Türkiye? How noise compliance is checked under TAREKS and which HS tariff codes are listed in Communiqué 2026/32 are explained on our Import into Türkiye page.

The Noise Certification Process Step by Step

  1. Identifying the equipment type in Annex I and whether Article 12 or Article 13 applies
  2. Selecting the applicable procedure (Annex V, VI, VII or VIII)
  3. Measuring noise according to the Annex III test code and determining the guaranteed sound power level
  4. Drawing up the technical documentation and, for Article 12, its assessment by the notified body
  5. Issue of the certificate of conformity, signing of the EC declaration of conformity, and affixing of the CE marking and noise label
  6. Periodical checking of production under Annex VI

Noise Certification Guides by Topic

Detailed guides from the TESTPLUS Technical Team on specific equipment and on each step of the 2000/14/EC procedure:

2000/14/EC Noise Certification for US and UK Manufacturers

Directive 2000/14/EC applies to all outdoor equipment placed on the EU market, wherever it is manufactured. US manufacturers of power generators, welding generators, compressors, construction machinery and lawn and garden equipment need a notified body for every Article 12 product before it can be CE marked and sold in the EU. TESTPLUS, 2000/14/EC notified body NB 2908, carries out the Annex VI, Annex VII and Annex VIII procedures and performs the noise tests with its own measurement equipment, on site at the manufacturer’s facility.

In Great Britain the Directive continues as the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001. Since the 2025 amendment came into force on 13 April 2026, CE marking is recognised there indefinitely, so equipment CE marked on the basis of a TESTPLUS (NB 2908) certificate can be placed on the GB market without a separate UKCA assessment; UKCA remains an alternative. Northern Ireland applies Directive 2000/14/EC directly (CE). One certificate therefore covers the EU, Great Britain and Northern Ireland. Read more in exporting outdoor equipment from the USA to the EU and outdoor equipment noise rules in the UK, or start with our Directive 2000/14/EC guide.

US office: +1 614 980 8975 · UK office: +44 7760 682877 · Request a quotation

Frequently Asked Questions About Noise Certification

What is a noise certificate?

A noise certificate is the document issued by a notified body at the end of noise certification, showing that outdoor equipment covered by Article 12 of the Outdoor Noise Directive 2000/14/EC complies with the noise limits and with the chosen conformity assessment procedure (Annex VI, Annex VII or Annex VIII). The guaranteed sound power level (LWA) is shown on the product next to the CE marking.

Is TESTPLUS a notified body for the Outdoor Noise Directive?

Yes. TESTPLUS is notified under the Outdoor Noise Directive 2000/14/EC with identification number 2908 (NB 2908) and is listed in the European Commission’s NANDO database. We carry out the notified body conformity assessment procedures for Article 12 equipment and provide voluntary third-party verification of the guaranteed sound power level for Article 13 equipment.

Which machines require a noise certificate?

Notified body assessment is mandatory for the 22 equipment types covered by Article 12, such as compressors (below 350 kW), power generators (below 400 kW), welding generators, excavators, loaders, dozers, mobile and tower cranes and lawnmowers. For Article 13 equipment no notified body is required; the manufacturer declares the guaranteed sound power level under Annex V internal control of production.

How is the guaranteed sound power level determined?

The sound power level is measured according to the test code in Annex III of the Directive, based primarily on EN ISO 3744. The guaranteed sound power level is obtained by adding the measurement uncertainty and the variations in series production to the measured value. For Article 12 equipment, this value must not exceed the limit calculated from the machine’s power or mass.

Which conformity assessment procedure should I choose?

For series-produced products the most common route is Annex VI (assessment of technical documentation and periodical checking). Annex VII unit verification suits one-off machines or small quantities, while manufacturers with an approved quality system may opt for Annex VIII full quality assurance.

Is a noise certificate required when importing into Türkiye?

Yes. Under Communiqué 2026/32 on the Import Inspection of Machinery, in force since 1 January 2026, the EC declaration of conformity and the noise certificate are requested in the TAREKS application for products subject to the noise regulation. For products on the Annex 2/A list, these documents must be endorsed by the Turkish Commercial Counsellor/Attaché in the country of dispatch.

Where is the noise measurement carried out?

Provided a suitable test area is available, measurements can be made at the manufacturer’s premises or at an open test site. TESTPLUS carries out noise measurements on site throughout Türkiye and abroad.

Is a 2000/14/EC certificate from TESTPLUS accepted in the UK?

Yes. In Great Britain, the 2001 Regulations as amended in 2025 (in force since 13 April 2026) continue to recognise CE marking indefinitely, so equipment CE marked on the basis of a TESTPLUS (NB 2908) certificate can be placed on the GB market without a separate UKCA assessment. In Northern Ireland, Directive 2000/14/EC applies directly and CE marking is required. See outdoor equipment noise rules in the UK.

Noise Certification with TESTPLUS

TESTPLUS is EU Notified Body No. 2908 under Directive 2000/14/EC and, accredited by TÜRKAK (AB-0155-U), performs conformity assessment under all three procedures: Annex VI, Annex VII and Annex VIII. With 19 years of experience, we carry out noise measurements on site throughout Türkiye and abroad; once the technical documentation has been assessed, the certificate of conformity is issued.

For a quotation or further information, please contact us.