Skip to main content

Summary: Article 12 of Directive 2000/14/EC covers equipment subject to noise limits: its guaranteed sound power level must not exceed the limit in the Article 12 table, and a notified body is involved in the conformity assessment. Article 13 equipment is subject to noise marking only.

The 57 types of equipment covered by Directive 2000/14/EC on noise emission are divided into two groups. Equipment listed in Article 12 is subject to a permissible sound power level, i.e. a limit value. Equipment listed in Article 13 has no limit value; only noise marking is mandatory. The manufacturer’s obligations and the need for a notified body follow from this distinction.

Article 12: Equipment Subject to Noise Limits

Construction machine under Article 12 of 2000/14/EC: excavator

The guaranteed sound power level of equipment in this group must not exceed the permissible sound power level set in the Directive. The 22 types of equipment under Article 12 include:

  • Builders’ hoists for the transport of goods (combustion-engine driven)
  • Compaction machines (vibrating and non-vibrating rollers, vibratory plates and vibratory rammers)
  • Compressors (below 350 kW)
  • Hand-held concrete breakers and picks
  • Construction winches (combustion-engine driven)
  • Dozers, dumpers, excavators, excavator-loaders, graders and loaders (below 500 kW)
  • Hydraulic power packs
  • Landfill compactors, loader-type with bucket (below 500 kW)
  • Lawnmowers, lawn trimmers and lawn edge trimmers
  • Combustion-engine driven counterbalanced lift trucks (excluding certain types)
  • Mobile cranes and tower cranes
  • Motor hoes (below 3 kW)
  • Paver-finishers (excluding those equipped with a high-compaction screed)
  • Power generators (below 400 kW) and welding generators

Article 13: Equipment Subject to Noise Marking Only

Garden equipment under Article 13 of 2000/14/EC: leaf blower and hedge trimmer

There is no limit value for the 41 types of equipment in this group, but the sound power level must be measured and the guaranteed value shown on the label. Typical examples:

  • Aerial access platforms with combustion engine
  • Portable chainsaws, brush cutters, hedge trimmers, leaf blowers and leaf collectors
  • Concrete and mortar mixers, truck mixers, concrete pumps
  • High-pressure water jet machines and high-pressure flushers
  • Hydraulic hammers, joint cutters, drill rigs, piling equipment
  • Refuse collection vehicles, sweepers, road milling machines
  • Water pump units (not for use under water)
  • Power generators of 400 kW and above
  • Electrically driven builders’ hoists and construction winches, conveyor belts

The complete and binding lists, with their power and capacity thresholds, are in the text of the Directive. Note that the same product family can fall under a different article depending on its power or drive type: a power generator below 400 kW is covered by Article 12, while one of 400 kW or above is covered by Article 13.

Comparison of Obligations

Obligation Article 12 Article 13
Sound power measurement according to Annex III Yes Yes
Permissible sound power level (limit) Yes No
Guaranteed sound power level label Yes Yes
CE marking and EC declaration of conformity Yes Yes
Conformity assessment procedure Annex VI, VII or VIII Annex V (internal control of production)
Notified body Mandatory Not mandatory

Article 13 Does Not Mean “No Obligations”

The absence of a limit value is often misread as the product being out of scope. In fact, for Article 13 equipment the manufacturer must still measure according to the method in Annex III, determine the guaranteed value, compile the technical documentation, affix the label and state the measured and guaranteed values in the declaration of conformity. The difference is that this is done under the manufacturer’s own responsibility, without a notified body.

Which Article Applies to Your Product?

  1. Identify which equipment definition in Annex I of the Directive your product matches.
  2. Check whether that definition appears in the Article 12 list or the Article 13 list.
  3. Check thresholds such as power, mass or cutting width; when a threshold is crossed, the article may change.
  4. If Article 12 applies, calculate the limit value and choose one of Annex VI, Annex VII or Annex VIII.

TESTPLUS carries out conformity assessment as a notified body (NB 2908) under Directive 2000/14/EC. For scope, see our Noise Emission (2000/14/EC) page.

Article 12 and Article 13: Frequently Asked Questions

Is a notified body required for Article 13 equipment?

No. For equipment under Article 13, the manufacturer may apply the internal control of production procedure in Annex V: it determines the guaranteed sound power level, affixes the noise marking and draws up the EC declaration of conformity. As there is no limit value for this equipment, notified body involvement is not mandatory. Manufacturers may still choose an independent third-party assessment on a voluntary basis.

Which procedures can be used for Article 12 equipment?

The manufacturer chooses one of Annex VI (internal control of production with assessment of technical documentation and periodic checking), Annex VII (unit verification) or Annex VIII (full quality assurance). A notified body is involved in all three.

Official Sources

This guide is part of the Outdoor Noise Directive 2000/14/EC certification resources of TESTPLUS, Notified Body NB 2908 (see our NANDO listing).